DUAL PURPOSE AIR DIFFUSER


DUAL PURPOSE AIR DIFFUSER

The SALOR Dual Purpose Diffuser provides higher standards of efficiency in air-moving techniques. This improved version of the well tried "SALOR" not only delivers air at or below room temperature without draught but also gives complete local control of both direction and volume.

Jet or diffused at will
Jet or Diffused at will
Wide angle flow control
Wide angle flow control

Moreover, owing to the specially designed slide-valve incorporated, 100% volume control is obtainable in any direction, and by complete rotation of the unit, either a jet of a diffused air flow is possible. Originally designed for marine use, the new SALOR is made of a non-hydroscopic moulded plastic in cream or ivory finish. It has an exceptionally clean surface finish and is not affected by dampness.


Based on ambient Still Air
Based on Ambient Still Air
End of Jet Assume 30 F.P.M.
(End of Jet Assume 30 F.P.M.)


These special characteristics have resulted in many applications, extending from its use in shipping installations to almost every sphere of the industry.


The capacities given below are based on the two pressures we recommend, 12.5 mm S.W.G. for normal systems or 7.6 mm S.W.G. for systems where extra quiet operations is required. The capabilities indicated are in the CFM and m³/min.



Type Nominal Cap 0.5"(12.7mm)S.W.G. Nominal Cap 0.3"(7.6mm)S.W.G. Nominal Outlet Diam. Min. Depth of Duct Dimensions     No. of Holes and Sizes P.C.D. of Screws
          A B C    
B 35
(1)
30
(0.8)
2"
(51mm)
3"
(76mm)
4 3/8"
(111mm)
2¾"
(70mm)
5 7/8"
(149mm)
3 x 3/16"
(3 x 5mm)
5"
(127mm)
C 65
(1.8)
50
(1.4)
2½"
(64mm)
3½"
(90mm)
6"
(127mm)
3¼"
(83mm)
6½"
(165mm)
3 x 3/16"
(3 x 5mm)
5 3/8"
(143mm)
D 95
(2.7)
75
(2.1)
3"
(76mm)
4"
(102mm)
5 5/8"
(143mm)
3 5/8"
(92mm)
7 1/8"
(181mm)
4 x 3/16"
(4 x 5mm)
6¼"
(159mm)
E 130
(3.7)
100
(2.8)
3½"
(90mm)
4½"
(114mm)
6 1/8"
(156mm)
4"
(102mm)
7 5/8"
(194mm)
4 x 3/16"
(4 x 5mm)
6¾"
(171mm)



Note : The dimension "a" is the diameter of the spigot in the duct. When the hole is cut, a small clearance should be allowed, i.e. plus 1/8" (3mm) on dimensions. This will allow rat proofing to be fitted if required.

The new Dual Purpose SALOR Diffuser has been designed to meet the Admirally Shock-proof Tests A and B.